Banking on monitoring to keep the Thames sweet

In terms of pollution, the Thames used to be a real stinker - excessive odour from it even led to the closure of Parliament in 1858. But these days the river is coming up smelling of roses, thanks to monitoring stations along its banks.


WATER QUALITY in the River Thames has been exerting an influence on human activity for centuries. In 1858, Parliament had to be suspended because of the stench arising from pollution in the river. But MPs’ noses are no longer necessary for detection of water pollution. A network of 60 sophisticated monitoring stations relay live water quality data from YSI sondes to the Environment Agency (EA) and other stakeholders.

Rising in Gloucestershire, flowing through the Cotswolds, passing Oxford and Windsor, the River Thames meets the North Sea after passing through London. With a length of 215 miles, the Thames is the longest river entirely in England. But the water quality of the river is constantly under threat. For this reason, the EA’s Matt Loewenthal believes the Thames and its major tributaries are more closely monitored than any other rivers in the world. In 1849, 14,000 Londoners died of cholera and fish could no longer survive in the polluted Thames estuary.

The Great Stink of 1858 was precipitated by the effects of the industrial revolution and sewage from London’s growing population.

This was recognised at the time and resulted in the construction of massive sewers to the north and south of the river. Similar huge undertakings took place to ensure water supply, with the building of reservoirs and pumping stations on the river to the west of London.

But, while these initiatives helped limit pollution levels, water quality remained poor into the 1960s. This was caused by the combined effects of inadequately treated sewage, industrial discharges, thermal pollution from power stations, and the extensive use of non-biological detergents.

Many parts of the estuary were considered biologically dead.

During the 1960s and 1970s, improvements were made at the two main sewage treatment plants at Crossness in south-east London and Beckton in east London, resulting in a dramatic improvement in water quality. Many different animals, birds and fish have returned to live and breed in the estuary.

Today there are 121 different species of fish and 170,000-plus birds in the estuary.

A colony of seahorses was recently discovered in the Thames and this has been hailed as definitive proof that water quality is improving. But Neil Dunlop of the EA says: “I’m not sure that a recent improvement in water quality is the main issue with the seahorses. We’re not quite sure why they’re here, but the river water has been clean enough for seahorses for some time. It could simply be down to improved monitoring.”

Pollution incidents

Matt Loewenthal manages the EA’s automated water quality monitoring network in the Thames region. Commenting on water quality trends in recent years, he says: “The decline of manufacturing industry in the region, coupled with investments and improvements in wastewater treatment systems have undoubtedly contributed to an overall improvement in Thames River water quality. But we regularly record pollution incidents that arise from combined sewer overflows (CSOs). These are detected by a sudden sags in dissolved oxygen, often in conjunction with a rise in ammonium.”

CSO is the discharge, during rainstorms, of untreated wastewater from a sewer system that carries both sewage and storm water. The increased flow caused by the storm water runoff exceeds the sewerage system’s capacity. The sewage is then forced to overflow into streams and rivers in the area through CSO outfalls.

Changing rainfall patterns caused by climate change, and urban development have meant that London’s 140-year-old sewage system is often unable to cope with the combined flow from the city’s sewage and storm water system.

Of the 57 CSOs in London, 36 are considered unsatisfactory in terms of frequency of discharge and/or environmental impact.

Even during periods of moderate rainfall, the overflows discharge storm water and sewage into the Thames on average once a week. About 20 million square metres of untreated sewage is discharged into the Thames every year.

Urban development, including new housing and roads, and the creation of non-porous parking areas in residential areas, have made a significant contribution to increasing levels of precipitation entering the drainage system.

But sustainable urban drainage systems (SUDS) now feature in many new developments. These initiatives will help prevent the sudden surges of influent at wastewater treatment plants.

Heavily used

Nevertheless, Loewenthal believes water quality in the Thames has reached a tipping point. He explains: “The River Thames and its major tributaries are the primary water resources in a catchment with a population in excess of 12 million people. There are more than 3,000 licensed abstractions of water, accounting for about 55% of effective precipitation. In addition, there are more than 10,000 consents to discharge sewage or trade effluent into the catchment. This means that, in terms of rainfall versus abstraction, the Thames is the most heavily used river in Britain.

“At the same time, climate change is creating more erratic weather conditions and

London is located in one of the driest parts of Britain with annual rainfall of 750mm. This is lower than Dallas, Texas. This heightens the significance of CSOs, and the decision to construct a £2B-plus underground tunnel to deal with the discharge from 36 London CSOs has not come a moment too soon.”

The government gave permission for the Tideway Tunnel in March 2007. The storage-and-transfer tunnel will run beneath the Thames from Hammersmith in west London. It will convey the discharges for collection and treatment in east London.

Illegal discharges
The new tunnel is not due for completion until 2020, and Loewenthal believes water quality monitoring will play a vital role in the intervening period.

He says: “Even after the tunnel is finished there will still be an important role for monitoring to play in the protection of the Thames from illegal discharges and failures to comply with discharge consents.”

As a consequence of the increasing environmental pressures on water resources, the Thames Region of the EA has developed a network of fixed, or fully mobile, automatic water quality monitoring stations (AWQMS). Each type has two common features.

Firstly, each station collects water quality data from a YSI water quality sonde. These sondes incorporate a number of sensors into a compact instrument. YSI sondes have been designed for users that require data from instruments that can be unattended for considerable periods of time.

Secondly, collected water quality data is transmitted to EA offices via telemetry. YSI normally provides this facility with the use of radio, mobile phone or satellite telemetry. But the EA in the Thames Region already operates a true real time system.

Environmental monitoring often takes place in remote locations, where coverage from mobile phone networks is incomplete and the topography or distances involved preclude conventional radio. This is why, for example, the EA is working with YSI on projects that use satellite telemetry. But in the Thames region the infrastructure is in place for a Meteorburst data collection system, which means the cost of adding further stations is minimal.

Meteorite activity

Data is transmitted via Meteorburst by bouncing signals off ionised particles high in the atmosphere that result from meteorite activity. Using this method it is possible to transmit data over distances of up to 370 miles.

Water quality data is collated centrally and can be accessed via the regional telemetry system or the internet – for selected stakeholders – via pc or PDA/BlackBerry.

According to YSI there are four basic types of AWQMS, all of which employ the same multiparameter water quality sonde:

  • Traditional brick buildings providing intake, surface and wastewater protection data to the EA, Thames Water and Vivendi
  • The Green Box is a transportable, drop-down system featuring state-of-the- art instrumentation that requires significantly reduced maintenance in the field
  • The Trailer system is a fully mobile AWQMS, providing the same data outputs as the above. It was developed in order to provide a flexible and cost-effective platform for short-term to medium- term deployments on problem discharge investigations and pollution incidents
  • The Suitcase System is a portable solution for short-term deployments on pollution incidents and investigations

Data from the AWQMS is described as real time because sampling takes place every 15 minutes. The procedure is as follows:

  • A pump from within the AWQMS draws river water into the sample chamber, which contains the YSI sonde, for four minutes. This ensures the sample is representative before a reading is taken from each of the sensors
  • Once a reading has been taken, the pump stops and backflushes to prevent any build up of solids
  • The telemetry unit then transmits the data via Meteorburst technology. The master station, at Newbury or Crystal Palace, automatically sends a return message once it has received and has checked the data
  • The data is then wiped from the telemetry unit until the next 15-minute data set

The YSI sonde does not therefore require internal memory in this application. But the EA has bought a quantity sondes with internal batteries and dataloggers so that water quality data can be saved for subsequent manual download when used as standalone loggers.

Three real time AWQMSs have been installed by the EA at the Olympic site with a further four YSI 6600 long-term logging sondes deployed to support data from six existing stations on the River Lee above the Olympic site.

These monitors are able to raise alarms should any part of the construction process cause unacceptable harm to water quality. Work can then be halted and the source of the problem identified and remedied. The stations are also helping Thames Water to protect and improve water quality in the area.

Appraisal teams

Each YSI sonde is loaded with sensors, monitoring things such as dissolved oxygen, temperature, pH, conductivity, turbidity, ammonium, blue-green algae and chlorophyll. The sonde is able to detect pollution from almost any source. Real time and historical data is also used by regulation, consenting, and ecological appraisal teams, as an additional risk management tool.

In contrast to spot sampling, continuous monitoring is able to detect pollution at any time, 24 hours a day, 365 days a year.

Pollution incidents may result in a loss of dissolved oxygen, which kills fish. But they will often also give rise to alterations in other parameters such as ammonium, turbidity and pH.

In addition to pollution from what are known as point sources, AWQMSs are being developed to monitor diffuse pollution. This is pollution that has many smaller sources occurring throughout a catchment. Not easily detectable in the short term, but made more obvious following an analysis of long-term trends.

A further advantage to long-term monitoring lies in its ability to provide a picture of the background water quality, so that any subsequent patterns in water quality can be judged according to whether they are normal with respect to diurnal, seasonal or climate change.

Perhaps one of the most important benefits of an integrated system that monitors an entire catchment is the ability to track events such as algae blooms. This is by using YSI chlorophyll sensors and new blue-green algae sensors. This, coupled with data from the turbidity and ammonium probes, is useful information for intake protection at water treatment plants. Operators may shut down intakes if, for example, algae or ammonia levels are too high. A network such as that on the Thames is able to provide advance warning of pollution.

Such comprehensive information is also valuable from an environmental perspective, because pollution events, such as fish kills or poor water quality, can be traced to a specific source.

Traditionally, one of the problems associated with long-term monitoring of natural water is biofouling. The EA has resolved this issue by employing YSI sondes, pumping samples into a test chamber, and by the inclusion of back-flushing in the monitoring routine.

In many other applications, particularly in those for which mains power for pumps is not available, it is necessary to deploy sondes that are capable of withstanding biofouling for extended periods. Under these circumstances YSI has developed an adaptation that incorporates small wipers that regularly clear the sensors of any fouling before readings are taken.

According to YSI, trials have found that unattended sondes are able to operate for up to three months, in even high-fouling conditions, when deployed with its extended deployment facility.

While Thames water quality has certainly improved, the river is still under pressure as a result of CSOs and high numbers of both abstractions for drinking water and consented discharges. But Lowenthal believes through the EA’s partnership with YSI they have been able to develop a highly effective monitoring network with the capability to monitor long-term trends and short-term pollution incidents.

As Loewenthal says: “If you don’t monitor it, you can’t manage it.”

www.ysihydrodata.com

Action inspires action. Stay ahead of the curve with sustainability and energy newsletters from edie